A Pad Mount or pedestal transformer is a ground-mounted electric power distribution transformer in a locked steel cabinet mounted on a concrete pad. Since all energized connection points are securely enclosed in a grounded metal housing, a pad mount transformer can be installed in places that do not have room for a fenced enclosure.
QXG Transformer
The pad-mounted transformers engineered and manufactured by QXG Transformer adhere to stringent standards such as IEEE, while also meeting efficiency requirements set by DOE and CSA. Customizable according to project specifications, our transformers can withstand harsh environments, including corrosion protection, low-temperature rise, and other demanding conditions, along with accommodating special design requirements.
We can do
Certificate: UL
Phases: Three
Frequency: 50 Hz, 60Hz
Standard: IEEE, CSA, ANSI, DOE
Type: Loop feed/Radial feed
Base rating: 45 kVA through 10,000 KVA
High Voltage (HV): 2.5 kV through 35 kV
Low Voltage (LV): 120 V through 25,000 V
Windings: Copper, Aluminum
HV Bushing: Live Front/Dead front/ Dead break
LV Bushing: Epoxy Bushings, Studs, Spades, Eyebolts.
Applicable Standard: | IEEE, ANSI, DOE, IEC |
Type: | Loop Feed |
Phase: | 3 |
Rated capacity: | 750KVA |
Input voltage: | 13.800Y/7970 |
Output voltage: | 480y/277 |
Frequency: | 60Hz |
Winding material: | Copper/Aluminum |
Iron Core: | Silicon steel grain oriented core |
Tap changer: | ±2×2.5% |
Cooling: | ONAN |
Temperature increase: | 65 ℃ |
Dielectric Oil: | Mineral Oil |
Tank: | Stainless steel/ Mild steel |
Fittings: | • Pad-lockable door handle • Lifting lugs • Externally clamped high- and low-voltage bushings • Pressure relief valve • Pressure vacuum gauge • Liquid temp gauge • Liquid level gauge • Drain and sample valve • Ground pads/lugs • Nitrogen blanket • other optional fittings |
Accessories
1. Fusing: Bayonet, Partial Range Current Limiting Fuse (CLF)
2. Fill/ Drain Provisions: Plug, Valve, Valve w/ Sampler
3. Gauges: Liquid Level, Liquid Temperature, Pressure Vacuum, Winding Temperature
4. Switching: Delta-Wye, Dual Voltage, 2 Position, 3 Switches, 4-Position, 4-Position
5. Pressure Relief Devices: Pressure Relief Valve, Cover Mounted Pressure Relief Device, etc.
1.Do you have UL certificate?
Yes, we have UL certificate for 1ph Pad Mounted Transformer and 3ph Pad Mounted Transformer.
2.Can you follow the IEEE standard?
Yes, our technicians are professional with IEEE, CSA, ANSI, DOE standard, we can produce the transformer depend on your requirements.
3.Do you have experience export to the USA, Latin America?
Yes, our main market is in the USA and Latin America and we have very good market reputations there.
4.Do you have other kind transformer?
Yes, we also have Pole Mounted Transformer, Distribution Substation Transformer, Dry Type Transformer, which can meet IEEE, CSA, DOE standard.
5.How long is your production time?
Normally 30-60 days, we have complete raw materials supply chain which can ensure the lead time and control the quality in each process.